X-Ray Generator |
- X-ray tube: rotating anode
- Dual focus (IEC): 0.3mm / 0.6mm
- Target angle: 10 Degrees
- Anode speed: 3450 RPM
- Max. anode heat content: 300 kHU / 22 kJ
- Max. anode heat dissipation: 870 W
- Generator type:
-Monoblock
-20 kHz high frequency
-Microprocessor-controlled
|
|
Operating Values |
- Nominal output (100 kV): 7.5 kW
- Maximum output: 7.5 kW
- Pulsed Fluoroscopy:
-kV range: 40-120 kV
-mA range: 1.5-75 mA
-pulse width: 4-30 ms, 8ms (in HQ mode without boost caps)
-pulse rate: 1, 2, 5, 10, 15, 30 pulses/s (60 Hz)
- Digital radiography (snap shot):
-kV range: 40-120 kV
-mA: up to 75 mA
- Radiography (not available without boost caps):
-kV range: 40-120 kV
-mA: up to 75 mA
-mAs: up to 250 mAs
|
|
Filtering |
- Total filtering: > 4.4 mm Al equivalent
|
|
Output |
- Pulsed fluoroscopy: up to 75 mA
- Digital radiography (snap shot):up to 75 mA
- Tube housing heat capacity:
-powered by integrated Advanced Active Cooling and heat management system
-5 million HU system heat capacity
-1200 W continuous dissipation and clinical performance
|
|
Collimator System |
- Iris collimator:
-9″ II – 2″-9″ (50-230 mm) diameter
-12″ II – 2-12″ (50-310 mm) diameter
- Slot collimator:
-9″ II – 2″-9″ (50-230 mm) diameter
-12″ II – 2-12″ (50-310 mm) diameter
- Virtual collimation without radiation
|
|
Image Intensifier |
- Type: cesium iodide
- DQE (IEC): 65%
- Conversion factor: 240 Cd
- Anti-scatter grid: Pb 8/40
|
|
9″ Intensifier |
- Central resolution 9″/6″/4″
- Contrast Ratio: 30:1
|
|
12″ Intensifier |
- Central resolution: 12″/9″ /6″
- Contrast Ratio: 22:1
|
|
Digital Video Camera |
- Active pixels: 1,048,576
- Camera matrix: 1024 x 1024 pixels
- Bandwidth of video signal: 20 MHz
- Bandwidth of video amplifier: 50 MHz
- Video (monitor): 1,125 lines
- Signal-to-noise ratio: 68 dB
- Control: ADR / AVR
|
|
Dimensions and Mechanics |
- Motor-driven vertical travel: 17″ (43cm)
- Horizontal travel: 9″ (22 cm)
- Orbital rotation:
-90 Degrees / +45 Degrees (9″ II) +25 Degrees (12″ II)
- Angulation: +/- 225 Degrees
- Swiveling (panning): +/- 10 Degrees
- Source/image receptor distance: 38″ (97 cm)
- C-Arm vertical free space: 30″ (76 cm)
- C-Arm depth: 27″ (68 cm)
- Width: 32″ (80 cm)
- Length: 74-83″ – 160 cm (9″ II) / 182 cm (12″ II)
- Height: 70-87″ – 170 cm (9″ II) / 214 cm (12″ II)
|
|
Brakes |
- Patented steering & braking lever, with parallel movement of the mobile stand in all directions
|
|
Real-Time Processing Functions: |
- Recursive filter: 4 levels
- Stack filter (Last Image Hold): 5 levels
- Edge enhancement filer: 5 levels
- Windowing and step windowing
- Digital image rotation and reversal without radiation
- Grayscale inversion
- Digital shutters
|
|
Application-Oriented Anatomical Programs: |
- Bone, Heart, Abdomen, Endo (optional)
- Motion, Metal, Soft, Large Patient
|
|
Image Acquisition |
- Autosave
- Cine loop with auto-playback (option)
-sequential image storage and display:
1, 2, 5, 10, 15, 20 frames/s
-start, stop and replay rate controls
|
|
DSA Package (optional – only available on systems with boost caps): |
- DSA real-time subtraction with re-masking capability
- MSA max. opacification sequence
- RSA roadmapping
- Pixel shift / landmarking
- Digital measurement functions (distance/angle)
|
|
Cine Loop |
- Sequential image storage and display
1, 2, 5, 10, 30 frames/s
- Cine loops start, stop and replay rate controls
|
|
Post Processing Functions |
- Edge enhancement: 5 levels
- Zoom: 3 levels
- Image rotation
- Windowing
- Grayscale inversion
- Image cropping (digital shutters)
|
|
Digital Memory |
- Storage capacity: up to 55,000 images
- Memory matrix: 1024 x 1024 pixels
- Image matrix: 1024 x 1024 pixels
- Digital image processing: up to 32 bit
- Grayscale: 4096 shades of gray (10 bit)
|
|
Data Organization |
- Patient-based data management with 16-image mosaic display
- pre-registration via DICOM worklist
- Manual input or emergency registration
- Air kerma dose display
- Air kerma value tagged to stored image
|
|
Monitors |
- Super-high-resolution and high-brightness twin flat-screen monitors
-screen size: 18.1″ (46 cm)
-native resolution: 1280 x 1024 pixels
-viewing angle (horizontal & vertical): 170 Degrees
-contrast ratio: 600:1
-Dimensions: 16 x 13 x 3″ (41 x 34 x 7 cm)
|
|
User Interface |
- TFT touchscreens on c-arm stand and monitor cart:
-synchronized
-intuitive icons for easy use
-multi-lingual user interface
|
|
Archiving |
- Video printer (optional): paper and film
- USB port:
-storage capacity depends on storage medium
-formats: DICOM, TIFF
-downsized formats: DICOM, JPG
- DVD-RW drive:
-4.7 GB storage capacity
-formats: DICOM, TIFF, Multimedia (AVI)
downsized formats: DICOM, JPG
- DICOM viewer software DVD and USB device
|
|
Networking |
- Ziehm NetPro (optional):
DICOM 3.0 interface (RJ45 or WLAN connection) for digital network integration
- “Primary Capture” mode
- Available DICOM Classes:
-Storage class incl. multiframe capability, storage commitment and media class
-Print class
-Worklist class incl. modality performed procedure step (MPPS)
-Query class
-Retrieve class
|
|
Options |
- Laser positioning device mounted on image intensifier and/or generator
- Emergency stop button
- Video output for external documentation
- Endo functionality:
-4 pedal foot switch
-landscape color monitor
-endoscope s-video connection
|
|
Weight |
- C-Arm mobile stand:
– 9″ – 838 lbs
-12″ – 877 lbs
- Monitor cart: 352 lbs
|