GE OEC 9600 C-Arm

Category:

The GE OEC 9600 C-Arm is known for its durability, versatility and excellent image quality. The OEC 9600 has been a staple in pain management centers worldwide, but can also be used for Orthopedics, Vascular and Neurovascular applications. There is also a Cardiac Super ‘C’ version of the OEC 9600 which is quite rare and is equipped with a special single leaf collimator for such applications.

Buy / Sell All Models


GE OEC 9600 C-Arm Specifications


Generator
  • High frequency
  • 4.0 kW full-wave
  • Up to 75 mA for radiographic film exposures
  • Continuous fluoro boost mode up to 12 mA (optional)
  • Pulsed fluoro mode
  • Pulsed fluorography mode up to 40 mA (optional)
  • Full power from outlet:
    • 50 Hz or 60 Hz
    • 100V-15A to 240V-8A
  • Patented energy buffer design

X-Ray Tube:
  • Rotating anode X-ray tube
  • Focal spots: 0.3 mm and 0.6 mm
  • Anode heat capacity: 300,000 HU
  • Anode cooling rate: 60,000 HU/min
  • Housing heat capacity: 1,600,000 HU
  • Anode diameter: 3.1″
  • Anode angle:
    • 8.5″ (9″ Image Intensifier)
    • 10″ (12″ Image Intensifier)
  • X-ray tube cooling fan (Vascular, Neurovascular & Cardiac units)

Collimator:
  • Iris collimation with dual opposing semi-transparent shutters allow elliptical, round and rectangular collimation
  • Iris and shutters are continuously variable
  • All functions remotely controlled from the C-Arm control panel

Fluoroscopy Mode:
  • Focal spot: 0.3 mm
  • kVp range: 40 – 120 kVp
  • mA range: 0.2 – 5.0 mA normal mode
  • mA range: 1.0 – 12 mA continuous fluoro boost mode
  • Auto and manual modes
  • Continuous, one-shot or pulsed operation
  • ABS varies mA, kVp and came

Fluoroscopy Mode:
  • Focal spot: 0.3 mm
  • kVp range: 40 – 120 kVp
  • mA range: 0.2 – 40.0 mA
  • Pulse rate: 1, 2, 4, or 8 pulses per second
  • Pulse width: 30 or 50 milliseconds
  • Computer controlled ABS, mA, kVp and camera gain

Video Imaging System


9″ Image Intensifier:
  • Tri-mode 9″/6″/4.5″ image intensifier
  • Minimum central resolution (at the monitor):
    • 9″: 1.4 lp/mm
    • 6″: 2.0 lp/mm
    • 4.5″: 2.4 lp/mm
  • DQE: 65% (typical)

12 in Image Intensifier (optional):
  • Tri-mode 12″/9″/6″ image intensifier
  • Minimum central resolution (at the monitor):
    • 12″: 1.0 lp/mm
    • 9″: 1.3 lp/mm
    • 6″: 1.6 lp/mm
  • DQE: 65% (typical)

Video Camera:
  • High resolution CCD camera
  • Full frame capture
  • 360° motorized rotation
  • On-screen orientation indicator (realtime feedback without fluoro)
  • Left-right image reversal
  • Top-bottom image reversal
  • Negative mode
  • Video signal: Standard RS 170A 60 Hz, 525 lines
  • Aspect ratio: 4:3
  • Computer controlled features:
    • Gain
    • Blanking
    • Camera iris

Video Monitors:
  • Dual 16″ square, black etched, anti-glare, anti-static
  • 525 lines/frame – 512 pixels
  • Ambient room light sensor
  • Multi-LED X-ray “ON” indicator
  • Remote window/level controls

Configuration Software Options


Software Options:
  • GSP – General Surgical Package
  • ESP – Expanded Surgical Package
  • Vascular Package (4/8/15 Frames Per Sec)
  • Neuro Vascular Package (30 Frames Per Sec)
  • Cardiac Package (30 Frames Per Sec)

Super-C: (optional):
  • Adds Extra 7″ Of Depth To Arc Of C-Arm
  • Allows 148 Degrees Of Orbital Rotation
  • Not Available With 12″ Image Intensifier

Additional Features


Hardcopy Options:
  • Thermal printer
  • External DICOM box
  • Image Capture Device
  • Laser aiming device

C-Arm Dimensions:
  • Height: 68″/86″ (1734 / 2191 mm)
  • Width: 33″ (838 mm)
  • Length: 78″ (1994 mm)
  • Weight: 720 lbs.

Workstation Dimensions:
  • Height: 64″ (1632 mm)
  • Width: 27″ (692 mm)
  • Depth: 27″ (692 mm)
  • Weight: 430 lbs.


Bluestone Diagnostics - Product Form